Conmem Gold M3

Specifications & Indications

Conmem Gold M3

  • Progressive Endodontic file system
  • Conmem Wire technology
  • Extremely flexible files
  • Files of choice for very narrow and calcified canals
  • Files of choice for severely curved canals
  • Minimal invasive files
  • Improved resistance to cyclic fatigue

Excellent Adaptation to Severely Curved Canals

Thanks to Conmem Wire Tech which allows for the superior flexibility , AF Rotary, as a special design for a severely curved canal, can negotiate to the root canal as well. Designed with a convex triangular cross section, help to enlarge the core diameter of the instrument for better torsional resistance.

Sequence System with Adaptive Instruments

Open File, Path File and Shaping Files are chosen in the package, for orifice access, patent establish and shaping, realize the process with only one box, to help you to save more time during instrumentation.

Indications

  1. Negotiate the coronal third of the canal with file K #10.
  2. Use Open File to prepare the coronal third and getting a straight line access.
  3. Irrigate the canal.
    With the use of apex locator, negotiate the canal with file K #10   in a watch-wind motion to full working length, to get a patent canal pathway.
  4. Irrigate the canal.
    Use C-path file (#19/0) to full working length in a pecking motion for 3 times   (Pecking motion: in and out motion for a depth of 3 mm).   Irrigate the canal, then repeat the process till reaching the full working length.
  5. Irrigate the canal.
    Use file  (#20/0) in a pecking motion to full working length.
  6. Irrigate the canal.
  7. Use file  (#25/0) in a pecking motion to full working length.
  8. Irrigate the canal.
  9. You can stop at this file, or if the canal needs more preparation, you can proceed with file (#30/0) in a pecking motion.

FAQ (Frequently Asked Question)

1. What are Healix Conmem M3 Gold Rotary NiTi files used for?

They are used in root canal treatment for cleaning and shaping the root canal system in accordance with Schilder’s objectives.

2. How are these files different from conventional NiTi rotary files?

Unlike traditional shape memory NiTi files, Healix Conmem files undergo a special heat treatment process that provides exceptional flexibility, high cutting efficiency, and up to 300% more resistance to cyclical fatigue.

3. What is the recommended speed and torque for using these rotary files?

The recommended parameters are Speed: 400 RPM and Torque: 2 Ncm.

4. What taper options are available in these files?

0.04 taper (One Ring)


0.06 taper (Two Rings)

5. How should I begin using the rotary files in a procedure?

Start with a #15 size hand file (2% taper) and an orifice opener, then use Healix Glide Path File (2%) to full working length before proceeding with flex files according to canal size.

6. What makes the cutting performance superior in these files?

The “S”-shaped cross section and sharp two-blade cutting edge enhance cutting efficiency while minimizing treatment time.

7. Do these rotary files have a safety feature?

Yes, they feature a non-cutting safety tip that helps reduce ledge formation, canal transportation, and apical extrusion of debris.

8. What packaging options are available?

They are available in Assorted Packs of 6 files or Individual Packs of 6 files.

9. Are these files suitable for all canal types?

Yes, they can be used for narrow, medium, and wide canals with specific file sequences recommended for each.

10. Why should I choose Healix Conmem Rotary Files over other brands?

They provide excellent flexibility, superior fracture resistance, faster cutting, progressive pitch design to prevent screw-in effect, and enhanced safety features—making root canal treatment safer and more efficient.